Brand Name :GFUVE
Model Number :GF312D1
Place of Origin :BEIJING,CHINA
MOQ :1SET
Payment Terms :T/T, Western Union, MoneyGram
Supply Ability :1500SETS/MONTH
Delivery Time :1-2WEEKS
Packaging Details :CARTON
accuracy :0.05%, 0.1%
resolution :6”TFT (640×480)
power supply :220V±10%, 50/60Hz
communication port :RS232
test voltage :Phase to Netural 0-480V (Phase to Phase 0-830V)
harmonic :2nd-64st
test current :0-12A
frequency :40-70Hz
dimension :245×162×60MM
weight :1.8KG
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description
1.Electrical parameters 
Accuracy class 0.05%, 0.1%
Display 6”TFT (640×480)
Power supply 220V±10%, 50/60Hz
Li-polymer battery (size (mm): 110x51x16, nominal output voltage: 7.2V, capacity: 5000mAh)
Power line supply (U1, UN), 85V-265V 50/60Hz
Communication port RS232
Test voltage
Range Phase to Netural 0-480V (Phase to Phase 0-830V)
Error ±0.05% (30V-480V)
±0.1% (5V-30V)
Voltage measurement temperature drift < 8 x 10 E-6/K
Voltage measurement relative humidity drift < 8 x 10 E-6/RH
Voltage measurement stability < 50 x10 E-6
Voltage measurement long term stability < 80 x 10 E-6/Year
Harmonic 2nd-64st
Test current
Range (direct connection) 0-12A
Error (direct connection) ±0.05% (100mA-12A)
±0.1% (10mA-100mA)
Range (clamp CT) 10mA-120A
Clamp CT Three Phase Electric Meter Calibration TFT Color LCD Electricity Energy Meter Model: Q13
Test range:1mA-120A
Accuracy:0.1%
Ratio:1000:1
Internal diameter:13mm
External diameter:33mm
Lead cable:2.5m
Three phase color label L1=Red,L2=Yellow,L3=Blue
Error (camp CT) ±0.1% (100mA-120A)
Current measurement temperature drift < 8 x 10 E-6/K @ 10mA-120A
Current measurement relative humidity drift < 8 x 10 E-6/RH@ 10mA-120A
Current measurement stability < 50 x10 E-6
Current measurement long term stability < 80 x 10 E-6/Year
Harmonic 2nd-64st
Power & Energy measure error
Active power (direct connection) ±0.05% (0.1A-12A)
±0.1% (0.01A-0.1A)
Reactive power (direct connection) ±0.1% (0.1A-12A)
Energy measure error
Active energy (direct connection) ±0.05% (0.1A-12A)
±0.1% (0.01A-0.1A)
Reactive energy (direct connection) ±0.1% (0.1A-12A)
Power/energy measurement temperature drift < 15 x 10 E-6/K
Power/energy measurement relative humidity drift < 12 x 10 E-6/RH@ 10mA-120A
Power/energy measurement stability < 100 x10 E-6
Power/energy measurement long term stability < 160 x 10 E-6/Year
Error display 5 digits with minimum three decimal places XX.XXX%
Phase angle
Range 0°-360°
Resolution 0.01o
Error ±0.05°
Frequency
Range 40-70Hz
Resolution 0.001Hz
Error 0.002Hz
Pulse input
Input channel 2
Input level 5-24V
Input frequency Max. 2MHz
Pulse output
Energy constant 180000imp/kWh, 1800imp/kWh, 180imp/kWh
Pulse ratio 1:1
Output level 5V
Pulse frequency Standard 400Hz-1KHz, customized max 10KHz
Scanning head
Three Phase Electric Meter Calibration TFT Color LCD Electricity Energy Meter Three Phase Electric Meter Calibration TFT Color LCD Electricity Energy Meter The sampler is equipped with a bracket which can clip/install on the tested electronic and electromechanical meters, and the sampler can insert to the ‘orifice/slot’ in the center of the bracket.
There are 3 status LED indicator:
[AUTO] – scan the turn-plate of the energy meter
[MANU] –Manual input pulse
[LED] – Receive the LED energy pulse
Function Sensitivity can be intelligently adjusted according to ambient light intensity to ensure accuracy measurement.
Function
Vector diagram Yes
Waveform Yes
Energy accumulation Yes
Communication with PC Yes
Overload protection Yes
2.Cable and Accessories
Test Cable Voltage test cable 1SET Cable Length:2m (R,Y,B,Black)
Current test calbe 1SET Cable Length:2m (R,Y,B,Black)
Plug Pin type 1SET (4black,2Red,2Yellow,2Green)
'U' type 1SET (4black,2Red,2Yellow,2Green)
'Ω' type 1SET (4black,2Red,2Yellow,2Green)
Crocodile type 1SET (1Black,1Red,1Yellow,1Green)
Accessories Bag Yes
3.Mechanical parameters
Instrument dimensions (W×H×D) (mm) 245×162×60
Instrument Weight (kg) 1.8
Carry case dimensions (W×H×D) (mm) 450×320×185
Carry case (kg) 10.6
4.Environmental conditions
Ambient temperature -10°C to 55°C
Relative humidity 15%-95%
Environmental protection level IP51
5.Standard
lsolation protection IEC 61010-1:2001
Energy measurement IEC 60736
Reference standard IEC 62052-11
IEC62053-21
IEC62053-22 & IEC62053-23
IEC61010-1:2001
6.Calibration and maintenance
Warranty 5 years
Calibration Lifelong free calibration service
Recommended calibration interval Every two years