FEATURES
| 1.Electrical parameters | ||
|---|---|---|
| Accuracy class | 0.05%, 0.1% | |
| Display | 6”TFT (640×480) | |
| Power supply | 220V±10%, 50/60Hz Li-polymer battery (size (mm): 110x51x16, nominal output voltage: 7.2V, capacity: 5000mAh) Power line supply (U1, UN), 85V-265V 50/60Hz | |
| Communication port | RS232 | |
| Test voltage | ||
| Range | Phase to Netural 0-480V (Phase to Phase 0-830V) | |
| Error | ±0.05% (30V-480V) ±0.1% (5V-30V) | |
| Voltage measurement temperature drift | < 8 x 10 E-6/K | |
| Voltage measurement relative humidity drift | < 8 x 10 E-6/RH | |
| Voltage measurement stability | < 50 x10 E-6 | |
| Voltage measurement long term stability | < 80 x 10 E-6/Year | |
| Harmonic | 2nd-64st | |
| Test current | ||
| Range (direct connection) | 0-12A | |
| Error (direct connection) | ±0.05% (100mA-12A) ±0.1% (10mA-100mA) | |
| Range (clamp CT) | 10mA-120A | |
| Clamp CT | Model: Q13Test range:1mA-120A Accuracy:0.1% Ratio:1000:1 Internal diameter:13mm External diameter:33mm Lead cable:2.5m | |
| Three phase color label | L1=Red,L2=Yellow,L3=Blue | |
| Error (camp CT) | ±0.1% (100mA-120A) | |
| Current measurement temperature drift | < 8 x 10 E-6/K @ 10mA-120A | |
| Current measurement relative humidity drift | < 8 x 10 E-6/RH@ 10mA-120A | |
| Current measurement stability | < 50 x10 E-6 | |
| Current measurement long term stability | < 80 x 10 E-6/Year | |
| Harmonic | 2nd-64st | |
| Power & Energy measure error | ||
| Active power (direct connection) | ±0.05% (0.1A-12A) ±0.1% (0.01A-0.1A) | |
| Reactive power (direct connection) | ±0.1% (0.1A-12A) | |
| Energy measure error | ||
| Active energy (direct connection) | ±0.05% (0.1A-12A) ±0.1% (0.01A-0.1A) | |
| Reactive energy (direct connection) | ±0.1% (0.1A-12A) | |
| Power/energy measurement temperature drift | < 15 x 10 E-6/K | |
| Power/energy measurement relative humidity drift | < 12 x 10 E-6/RH@ 10mA-120A | |
| Power/energy measurement stability | < 100 x10 E-6 | |
| Power/energy measurement long term stability | < 160 x 10 E-6/Year | |
| Error display | 5 digits with minimum three decimal places XX.XXX% | |
| Phase angle | ||
| Range | 0°-360° | |
| Resolution | 0.01o | |
| Error | ±0.05° | |
| Frequency | ||
| Range | 40-70Hz | |
| Resolution | 0.001Hz | |
| Error | 0.002Hz | |
| Pulse input | ||
| Input channel | 2 | |
| Input level | 5-24V | |
| Input frequency | Max. 2MHz | |
| Pulse output | ||
| Energy constant | 180000imp/kWh, 1800imp/kWh, 180imp/kWh | |
| Pulse ratio | 1:1 | |
| Output level | 5V | |
| Pulse frequency | Standard 400Hz-1KHz, customized max 10KHz | |
| Scanning head | ||
![]() | The sampler is equipped with a bracket which can clip/install on the tested electronic and electromechanical meters, and the sampler can insert to the ‘orifice/slot’ in the center of the bracket. There are 3 status LED indicator: [AUTO] – scan the turn-plate of the energy meter [MANU] –Manual input pulse [LED] – Receive the LED energy pulse | |
| Function | Sensitivity can be intelligently adjusted according to ambient light intensity to ensure accuracy measurement. | |
| Function | ||
| Vector diagram | Yes | |
| Waveform | Yes | |
| Energy accumulation | Yes | |
| Communication with PC | Yes | |
| Overload protection | Yes | |
| 2.Cable and Accessories | ||
| Test Cable | Voltage test cable 1SET Cable Length:2m (R,Y,B,Black) Current test calbe 1SET Cable Length:2m (R,Y,B,Black) | |
| Plug | Pin type 1SET (4black,2Red,2Yellow,2Green) 'U' type 1SET (4black,2Red,2Yellow,2Green) 'Ω' type 1SET (4black,2Red,2Yellow,2Green) Crocodile type 1SET (1Black,1Red,1Yellow,1Green) | |
| Accessories Bag | Yes | |
| 3.Mechanical parameters | ||
| Instrument dimensions (W×H×D) (mm) | 245×162×60 | |
| Instrument Weight (kg) | 1.8 | |
| Carry case dimensions (W×H×D) (mm) | 450×320×185 | |
| Carry case (kg) | 10.6 | |
| 4.Environmental conditions | ||
| Ambient temperature | -10°C to 55°C | |
| Relative humidity | 15%-95% | |
| Environmental protection level | IP51 | |
| 5.Standard | ||
| lsolation protection | IEC 61010-1:2001 | |
| Energy measurement | IEC 60736 | |
| Reference standard | IEC 62052-11 IEC62053-21 IEC62053-22 & IEC62053-23 IEC61010-1:2001 | |
| 6.Calibration and maintenance | ||
| Warranty | 5 years | |
| Calibration | Lifelong free calibration service | |
| Recommended calibration interval | Every two years | |