Brand Name :GFUVE
Model Number :GF1021
Place of Origin :BEIJING,CHINA
MOQ :1SET
Payment Terms :T/T, Western Union, MoneyGram
Supply Ability :1500SETS/MONTH
Delivery Time :1-2WEEKS
Packaging Details :CARTON
accuracy :0.05%, 0.1%
power supply :One Phase AC 85-265V, frequency 50/60Hz.
voltage range :57.7V, 100V, 220V, 380V; max 500V
current range :200mA, 1A, 5A, 20A, 100A; max 120A
frequency :40Hz-70Hz
harmonic :2-51times
dimension :325×275×135mm
weight :8kg
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

FEATURES

  • Accuracy class 0.05
  • 0-120A, 0-500V
  • Test 3pcs or 2pcs meter synchronously
  • Start testing and creep testing
  • Reference standard and power source integrated
  • Test by automatic or manual
  • 7 inch TFT touch screen
  • Weight light 8Kg
  • Recorder 500 sets energy meter data
  • Overload, short circuit, open circuit protection

TECHNICAL PARAMETERS

Electrical parameters 
Accuracy class 0.05%, 0.1%
Power supply One Phase AC 85-265V, frequency 50/60Hz.
AC Voltage output 
Range 57.7V, 100V, 220V, 380V; max 500V
Adjustment range (0-120)%RG(1)
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability 0.01%/120s
Distortion 0.1% (Non-capacitive load)
Output load max 30VA
Measuring accuracy 0.05%RG
AC Current output 
Range 200mA, 1A, 5A, 20A, 100A; max 120A
Adjustment range (0-120)%RG
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability <0.01%/120s
Distortion ≤0.1% (Non-capacitive load)
Output load max 50VA
Accuracy 0.05%RG
Power output 
Active power output stability <0.01%RG/120s
Reactive power output stability <0.02%RG/120s
Active power measuring accuracy 0.05%RG
Reactive power measuring accuracy 0.1%RG
Phase Output
Output adjustment range 0°-359.99°
Output adjustment fineness 10, 1, 0.1, 0.01 as optional.
Resolution 0.01°
Accuracy 0.03°
Power factor
Adjusting range -1 ~ 0 ~ 1
Resolution 0.0001
Measurement accuracy 0.0005
Frequency Output
Adjustment range 40Hz-70Hz
Output adjustment fineness 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution 0.001Hz
Accuracy 0.005Hz
Voltage /Current/Harmonic Setting
Harmonic number 2-51times
Harmonic content 0-40%
Harmonic phase 0-359.99
Harmonic setting accuracy (10%±0.1%)RD(2)
Power Energy Measurement Error
Active power energy 0.05%RG
Reactive power energy 0.1%RG
Power Pulse Output
Power pulse type active pulse, reactive pulse
Active power pulse output 5V,10mA
Power Pulse Input
Energy pulse type support active and reactive pulse, the highest frequency power
pulse input is 180K.
Mechanical parameters
Dimensions (W×D×H) (mm) 325×275×135
Weight (kg) 8
Environmental conditions
Ambient temperature -10°C to +50°C
Relative humidity 35%-85%