GF6019 Programmable DC Power Calibrator for calibration of DC voltage meter, DC current meter & DC power meter
Programmable DC sources are an imperative tool in any test or research lab due to the need to calibrate the plethora of devices that measure such signals. GFUVE's expertise in delivering high quality instrumentation is evidenced by the introduction of the GF6019, which combines high precision outputs, simple controls, and powerful features to meet all your calibration needs.
A high accuracy programmable DC power calibrator suitable for calibrating single-phase dc watt-meters, power meters, and kW-Hr meters. The GF6019D is a practical solution to precision power simulation, providing a simultaneous supply of voltage and current with phase control.
The GF6019 is designed calibration of traditional voltage and current measuring devices such as ammeters, voltmeters, digital multimeters, and DC wattmeters. In addition, the GF6019 is capable of calibrating temperature meters and controllers which measure temperature through thermocouples or Resistance Temperature Detector's (RTD).
A voltage source is a device which provides a constant voltage to load at any instance of time and is independent of the current drawn from it. This type of source is known as an ideal voltage source. Practically, the ideal voltage source cannot be made. It has zero internal resistance. It is denoted by this symbol. The graph represents the change in voltage of the voltage source with respect to time. It is constant at any instance of time.
FEATURES AND FUNCTIONS
- Testing all kinds of DC energy meter, DC power meter
- Testing all kinds of DC ammeter, DC voltmeter
- DC current source and DC voltage source
- User friendly menu guided operation
- Especially configured USB stick for storage of customer data
- Easy verification and analysis of DC meter
- Automatic operation without need of an external PC
- Accuracy class 0.02
- 0-30A/0-1050V
- Start testing and creep testing
- DC power source integrated
- Test by automatic or manual
- 8 inch TFT touch screen
- Recorder 10000 sets energy meter data
- Overload, short circuit, open circuit protection
PARAMETERS
Electrical parameters |
Accuracy | 0.02% |
Power Supply | One Phase AC 180-265V, frequency 50/60Hz. |
DC Voltage Output |
Range | 65V, 250V, 500V, 750V, 1000V (max 1150V) |
Adjustment range | (0-120)%RG(1) |
Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | 0.01%/120s |
Distortion | 0.1% (Non-capacitive load) |
Output load | 50VA |
Full load regulation rate | ≤±0.01%RG |
Accuracy | ±(0.03%RD+0.02%RG) |
DC Current Output |
Range | 0.001A, 0.005A, 0.02A, 0.05A, 0.2A, 1A, 3A, 10A, 20A, 30A, (max 36A) small signal 2.5mV, 20mV, 100mV, 1V, 5V |
Adjustment range | (0-120)%RG |
Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | <0.01%/120s, small signal 2uV/min |
Distortion | ≤0.1% (Non-capacitive load) |
Output load | 1200VA |
Full load regulation rate | ≤±0.01%RG |
Accuracy | ±(0.02%RD+0.02%RG) |
Externally attached shunt | 100mV |
Accuracy | ±(0.02%RD+0.02%RG) |
DC Power Output |
power output stability | <0.01%RG/120s |
power accuracy | ±(0.02%RD+0.02%RG) |
DC Power Energy Measurement Error |
power energy | ±(0.02%RD+0.02%RG) |
Power Pulse Output |
Power Pulse Output | 20KHz (Full-Range) |
Power Pulse Input |
Energy pulse input | 20KHz |
Ripple output | 20-500Hz ripple output |
Communication port | USB port, RS232, 10/100M LAN |
Mechanical parameters |
Dimensions (W×D×H) (mm) | 430x400x250 |
Weight (kg) | 12 |
Environmental conditions |
Ambient temperature | -10°C to +40°C |
Relative humidity | -30°C to 60°C |
(1) RG means range, the same as below; (2) RD means the setted harmonic content, harmonic can be a single output, also multiple output. |