Add to Cart
S50 1200A 1MV/A and 1mA/A Output AC Current Clamp On Current Transformer 0.1% for Class A PQA
The round jaw design on the S50 Series AC current clamp on CT along with the high content nickel metal core makes them well suited for power quality applications where high accuracy and low phase shift along with wide frequency are important from 10Hz to 10MHz. Measurement range is 1mA to 1200A. The S50 is a general purpose 1200A AC current clamp on CT designed for use with DMMs, power loggers and energy meter calibration instruments that have a current input. It has a 1000:1 ratio and output of 1mA per amp or 1mV per amp measured in the jaw. The S50 clamp on CT has an integral 2.5m lead terminated. The rounded jaw design on this current clamp makes it well-suited for power applications where high accuracy 0.1% and low phase shift and wide frequency response are important. .
Clamp-On Current Transformers GFUVE® maintains a large in-stock inventory of Clamp-On Current Transformers including AC, Micro Clamp and Clamp-On CT Accessories for most common applications. Below is a list of all clamp-on current transformers available through GFUVE material, however, not all models are in-stock.
Clamp-On Current Transformers are the one-handed operating solution for temporary energy audits or long-term energy studies. The GFUVE 1200A Clamp On Current Transformer is specifically designed to offer broad utility in a compact shape. These CTs deliver high-accuracy, high-sensitivity, versatility, and low phase shift.
Electrical parameters | ||
---|---|---|
Ratio | 1000: 1 , 2000:1, 1000:5 (customized) | |
Accuracy class | 0.1%, 0.2%, 0.5% | |
Primary current | 0 - 500A AC and 0-1000A AC | |
Signal output | 1mV/A, 1mA/A | |
Secondary voltage | 0 - 0.5V AC and 0 - 1V AC; | |
Secondary current | 0-1A or 0-5A AC | |
Max. Cont. Input current | 1200A | |
Load capacity | ≤4Ω | |
Over voltage category | CAT III 600V | |
Frequency range | 10Hz-10MHz | |
Dielectric strength | 3KV 50Hz/60Hz at 1minute | |
Temperature range | -40°C to +55°C | |
Output | 2.5 meter cable with D01 or BNC connector | |
Max. voltage not insulated conductors | 600 V | |
Standard | EN 61010-1, EN 61010-2-032, IEC60044-1 | |
Installation | clamp type | |
Output mode | lead output(2.5m) | |
Accuracy (1000A Range) | ||
0-10A | ≤0.5% | |
10-100 | ≤0.2% | |
10-1200A | ≤0.1% | |
Phase Shift(1000A Range) | ||
0-10A | ≤0.5° | |
10-100 | ≤0.2° | |
100-1200A | ≤0.1° | |
Mechanical parameters | ||
Dimensions (L x W x H) (mm) | 105 x 218 x 30 | |
Weight (g) | 650 | |
Holding wire diameter (mm) | φ52 | |
Max. jaw opening (mm) | 52 | |
Jaw color | Red & Grey | |
Material | PC+ABS, UL94 V0 |