Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd. an exclusive current transformer, split core current transformer, current clamp & voltage transformer manufacturer.

Manufacturer from China
Active Member
8 Years
Home / Products / Electrical Test Equipment /

Single Power Source Electrical Test Equipment Clamp Type Multimeter Calibrator GF6018A

Contact Now
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
City:beijing
Province/State:beijing
Country/Region:china
Contact Person:Andy
Contact Now

Single Power Source Electrical Test Equipment Clamp Type Multimeter Calibrator GF6018A

Ask Latest Price
Video Channel
Brand Name :GFUVE
Model Number :GF6018A
Place of Origin :China
MOQ :1
Payment Terms :T/T, Western Union
Supply Ability :500
Delivery Time :1-2Week
Packaging Details :Standard Wooden Case
Power supply :Single phase AC 220V±10% or 110V±10%, 50/60HzAC
AC Current range :200mV, 400mV, 2000mV, 4000mV, 20V, 100V, 200V, 500V, 1000V
AC Voltage Range :2mA, 4mA, 20mA, 40mA, 0.2A, 0.5A, 2A, 5A, 10A, 20A
Range :45-65Hz
Fineness :0.001Hz
Times :2-31
Extent :0-20%
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Clamp Type Multimeter Calibrator GF6018A

The equipment is compliance with national verification regulation: JJG124-2005 “Ammeter, voltmeter, power meter and resistance meter verification rules” and related national standards. 0.05 single-phase AC/DC standard source, can verify magnitude 0.2 and the following AC/DC voltmeter, ammeter, frequency meter, resistance meter. The source signals by using DSP and 16-bit high-speed analog-to-digital converters of controllable sine wave, the distorted wave signal source.The equipment comes with RS-232 interface, can be connected with PC to a semi-automatic verification system. It has precise interface and multi-functions including verification, storage and query.The equipment adopts color LCD screen, chart character display is clear, with high precision, stable and reliable, convenient operation and flexible characteristics.

FEATURES

  • It can be semi-automatic or manual inspection of analog multi meter, clamp type current meter, all kinds of electric meter, (voltmeter, ammeter, frequency meters, resistance meter) basic error
  • The equipment can be generated with 2-31 harmonic wave, harmonic number, order, amplitude and harmonic phase of fundamental wave can be programmed
  • Power amplifier working frequency range is 40Hz-1KHZ, has a good linear. Current amplifier is constant current source; voltage amplifier is constant voltage source. Because of light weight, this device is more suitable for field use
  • With RS-232 interface, this device is controlled by PC through the PC software (optional), can be automatic or manual inspection, and the results are processing and management
  • Has a non-volatile memory, it can store 500 pieces of the raw data of tested meter, for access and upload
    Electrical parameters  
    Power supply Single phase AC 220V±10% or 110V±10%, 50/60HzAC
    AC Voltage output  
    range 200mV, 400mV, 2000mV, 4000mV,
    20V, 100V, 200V, 500V, 1000V
    Range 20V-1000V Accuracy ±(0.03%RD+0.02%FS)
    Stability ≤0.01% FS /60s
    Range 200mV-4000mV Accuracy ±(0.3%RD+0.2%FS)
    Stability ≤0.04% FS /60s
    Load capacity 20VA
    Waveform distortion ≤0.3%
    Adjustable Range 0-120% FS (1000V not included)
    Fineness 5×10-5
    AC Current Output  
    Range 2mA, 4mA, 20mA, 40mA, 0.2A, 0.5A, 2A, 5A, 10A, 20A
    Range 0.2A-20A Accuracy ±(0.03%RD+0.02%FS)
    Stability ≤0.01% FS /60s
    Range 2mA-40mA Accuracy ±(0.3%RD+0.2%FS)
    Stability ≤0.04% FS /60s
    Load capacity 20VA
    Waveform distortion ≤0.3%
    Adjustable Range 0-120% FS
    Fineness 5×10-5
    Frequency Output  
    Range 45-65Hz
    Fineness 0.001Hz
    Accuracy 0.01Hz
    Harmonic Wave  
    Times 2-31
    Extent 0-20%
    Each harmonic phase fineness 0.01·N (N is harmonic order)
    DC voltage output  
    Range 200mV, 400mV, 2000mV, 4000mV,
    20V, 40V, 100V, 200V, 400V, 1000V
    Load capacity 20W
    Adjustable range 0-110% FS (1000V not included)
    Adjustable fineness 5×10-5
    Stability ≤0.01% FS /60s (peak-peak value)
    Accuracy ±(0.03%RD+0.02%FS)
    Ripple wave ≤1% FS
    DC current output  
    Range 20uA, 40uA, 200uA, 400uA, 2mA, 4mA,
    20mA, 40mA, 0.2A, 1A, 2.5A, 5A, 10A, 20A
    Load capacity 20W
    Adjustable Range 0-110% FS (1000V not included)
    Adjustable Fineness 5×10-5
    Stability ≤0.01% FS /60s (peak-peak value)
    Accuracy ±(0.06%RD+0.04%FS)
    Ripple wave ≤1% FS
    Resistance box  
    Range 0-200Ω, 200-400Ω, 0-2kΩ, 2kΩ-4kΩ, 0-20kΩ, 20kΩ-40kΩ,
    0-200kΩ, 200kΩ-400kΩ, 0-2MΩ, 2MΩ-4MΩ
    Fineness 0.02%
    Range 0-2kΩ, 0-20kΩ, 0-200kΩ  
    Range 0-2kΩ Adjustable Range 0-100%FS
    Accuracy ±(0.12%RD+0.08%FS)
    Range 0-200Ω,0-2MΩ Adjustable Range 0-100% FS
    Accuracy ±(0.3%RD+0.2%FS)
    Range 2kΩ-4kΩ, 20kΩ-40kΩ, 200kΩ-400kΩ  
    Range 2kΩ-4kΩ Adjustable Range 5%-100%FS
    Accuracy ±(0.12%RD+0.08%FS)
    Range 200-400Ω,
    2MΩ-4MΩ
    Adjustable Range 5%-100% FS
    Accuracy ±(0.3%RD+0.2%FS)
    Clamp meter range  
    200A Accuracy ±0.2%
    600A Accuracy ±0.5%
    1000A Accuracy ±1%
    Dot frequency square wave output 
    Range 1kHz, 5kHz, 10kHz, 50kHz, 100kHz, 200kHz, 1000kHz
    Square wave amplitude 4.5V
    Setting accuracy 5×10-5
    Mechanical parameters  
    Dimension (L×W×H) (mm) 440x360x160