Add to Cart
120A 500V Three Phase Portable Energy Meter Test Equipment Bench With Harmonic and Scanning Head
The Three Phase Energy Meter Test Bench system described hereby can test / calibrate 1 to 24, three phase and single phase energy meters, which reference accuracy is 0.02%, can test energy meters (MUT) with accuracy 0.1%, 0.2%, 0.5 (s) %, 1.0%, 2.0%.
The GF302D is a powerful and portable three phase current and voltage source. All test values are generated absolutely synthetically with a high degree of accuracy, low phase shift and stability. The source is available in 12 A, 24A or 120 A.
The GF302D three phase portable power source is a lightweight and portable three phase current and voltage source based on newest technology and serves for solving this problem by simulating the required load conditions. Operation is performed by integrated 7“ touch screen or via keyboards.
It is suitable for power department, measuring department, quality control department, research units, and institutions of higher learning, and electric energy meter, power distribution terminals, power supply management, load control, power quality, reactive power compensation device and the production of enterprise etc.
Electrical parameters | |
---|---|
Accuracy class | 0.02%, 0.05%, 0.1% |
Power supply | Single phase AC 85-265 V, frequency 50/60 Hz |
AC Voltage output | |
Range (U1, U2, U3 phase) | 57.7V/100V/220V/380V; range switch automatically(Max 500V) |
Adjust fineness | 0.01% RG |
Accuracy | 0.05% RG |
Stability | <0.01% RG/120s |
Distortion degree | <0.3% (not capacitive load) |
Output power | 25VA |
Full load regulation rate | 0.01% RG |
Full load regulation time | Less than 1mS |
Long-term stability | ± 60 PPM/year |
AC Current output | |
Range (I1, I2, I3 phase) | 0.2A, 1A, 5A, 20A, 100A; range switch automatically |
Adjustment range | (0-120)%RG |
Adjust fineness | 0.01% RG |
Accuracy | 0.05% RG |
Stability | <0.01% RG/120s |
Distortion degree | <0.3% (not capacitive load) |
Output power | 45VA |
Full load regulation rate | 0.01% RG |
Full load regulation time | Less than 1mS |
Long-term stability | ± 60 PPM/year |
Power output | |
Accuracy | 0.05% RG |
Stability | 0.01% RG/120s |
Phase angle | |
Adjusting range | 0°-359.99° |
Resolution | 0.001° |
Accuracy | 0.05° |
Power factor | |
Adjusting range | -1 ~ 0 ~ +1 |
Resolution | 0.0001 |
Accuracy | 0.0005 |
Frequency | |
Adjusting range | 40-65 Hz |
Resolution | 0.001 Hz |
Accuracy | 0.005 Hz |
Temperature drift | ± 0.5 PPM/°C |
Long-term stability | ± 4 PPM/year |
Harmonic accuracy | |
Harmonic phase | 0°-359.99° |
Harmonic phase accuracy | < 0.01° |
Harmonic set accuracy | 0.1% (relative to the base wave ratings) |
Mechanical parameters | |
Dimensions (W×D×H) (mm) | 500x600x175 |
Weight (kg) | 27 |
Environmental conditions | |
Working temperature | 0°C to 40°C |
Storage condition | -30°C to -60°C |
Relative humidity | ≤ 85% |
NO. | Accuracy | Voltage range | Current Range | Weight |
---|---|---|---|---|
302D1201 | 0.10% | 0-500V | 0-120A | 27KG |
302D12005 | 0.05% | 0-500V | 0-120A | 27KG |
302D1201 | 0.10% | 0-380V | 0-12A | 18KG |
302D1205 | 0.05% | 0-380V | 0-12A | 18KG |
302D2401 | 0.10% | 0-500V | 0-24A | 20KG |
302D2405 | 0.05% | 0-500V | 0-24A | 20KG |