GF312B Portable Electric Energy Meter Calibration Device is used to calibrate three phase, single phase, active and reactive watt meters. And it also can be used as voltage, current and power meter to measure AC parameters of three phase power line.It can measure wave distortion factor and 2nd to 63th harmonic wave. it is high precision 0.05%, measurement current 0-24A directly, 0-120A or 0-3000A with clamp on ct. 100A clamp on ct has software compensation, the precision can reach 0.05%.
GFUVE Electronics is a recognized world leader of Energy Reference Standards, Meter Test Boards, CT / PT Meter Field Testers, DC / AC Transfer Standards, Energy Meter Testing and our Automated Laboratory Energy Reference Systems. GFUVE Electronics is 100% committed to exceeding the requirements of its Customers through continual improvement of all our products and services.
Application
The devices used to calibrate electricity meters must be routinely verified themselves. That’s the only way to protect consumers. Laborelec’s working standards are well suited to the task. We can carry out calibration on your site, minimising disruption to your calibration routine.
Laborary has a fully equipped calibration equipment with the most accurate energy standard. It can furnish an extensive accreditation portfolio that is recognised internationally.
Power plant
Power company
Electric power measurement department
Electric Energy Laboratory
Metrological verification department
Petroleum and petrochemical enterprises
Steel and cement plant
Power commissioning company
Electrical parameters | |
---|---|
Accuracy class | 0.05, 0.1%, 0.2% |
Power supply | 220V ± 10% or 110V ± 10%, 50/60Hz ± 2Hz |
Test Voltage | |
Range | 0V-600V |
Error | ±0.05% (30V-600V) ±0.1% (5V-30V) |
Harmonic | 2nd-63st |
Test Current | |
Range (direct connection) | 20mA-20A |
Error (direct connection) | ±0.05% (100mA-20A) ±0.1% (20mA-100mA) |
Range (Clamp CT) | 10mA-3000A |
Error (Clamp CT) | ±0.2% (100mA-3000A) ±0.5% (10mA-100mA) |
Harmonic | 2nd-63st |
Power measure error | |
Active power (direct connection) | ±0.05% (0.1A-20A) ±0.1% (0.02A-0.1A) |
Reactive power (direct connection) | ±0.1% (0.1A-20A) |
Energy measure error | |
Active energy (direct connection) | ±0.05% (0.1A-20A) ±0.1% (0.02A-0.1A) |
Reactive energy (direct connection) | ±0.1% (0.1A-20A) |
Phase angle | |
Range | 0° ~ 360° |
Resolution | 0.01° |
Error | ±0.05° |
Frequency | |
Range | 45Hz-65Hz |
Resolution | 0.001Hz |
Accuracy | 0.005Hz |
Power factor | |
Range | -1 ~ 0 ~ 1 |
Resolution | 0.0001 |
Error | 0. 0005 |
Pulse output | |
Energy constant | 180000imp/kWh, 1800imp/kWh, 18imp/kWh |
Pulse ratio | 1:1 |
Output level | 5V |
Pulse input | |
Input channel | 1 |
Input level | 5-24V |
Input frequency | Max. 2MHz |
Display | |
Resolution | 6”TFT (640×480) |
Function | |
Vector diagram | Yes |
Waveform | Yes |
Energy accumulation | Yes |
Communication port | RS232 |
Communication with PC | Yes |
Mechanical parameters | |
Dimensions (W×H×D) (mm) | 390×200×160 |
Host Weight (mm) | 3 |
Weight (including Accessories 3pcs 100A clamp CT) (kg) | 12 |
Environmental conditions | |
Ambient temperature | -10°C to 40°C |
Relative humidity | 30%-85% |