Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd. an exclusive current transformer, split core current transformer, current clamp & voltage transformer manufacturer.

Manufacturer from China
Active Member
8 Years
Home / Products / CT PT Analyzer /

4.8KG Weight CT PT Analyzer Voltage Transformer Analyzer 0.02% / 0.05% Accuracy

Contact Now
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
City:beijing
Province/State:beijing
Country/Region:china
Contact Person:Andy
Contact Now

4.8KG Weight CT PT Analyzer Voltage Transformer Analyzer 0.02% / 0.05% Accuracy

Ask Latest Price
Video Channel
Brand Name :GFUVE
Model Number :GF1061PT
Certification :CE, ISO9001
Place of Origin :BEIJING CHINA
MOQ :1SET
Price :Negotiable
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :200SETS/MONTH
Delivery Time :2-3weeks
Packaging Details :Standard Export Wooden Box
Name :voltage transformer Analyzer
Application :ct and pt test
Theory :DC variable-frequency methods
LCD :7inch TFT touch color LCD
Accuracy :0.02% or 0.05%
Reference standards :IEC60044-1, IEC60044-6, IEC61869-2, ANSI/IEEE C57.13
Ratio error :0.05%
Weight :4.8KG
Overall dimension (L x W x H) (mm) :280 x 250 x 160mm
Usage :voltage transformer or potential transformer
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IEC60044-2 & IEC61869-1, 3 GF1061PT Portable CT PT voltage transformer Analyzer with printer

GF1061PT Portable GFUVE potential transformer Analyzer with PT testing function, current transformer testing

GF1061 portable GFUVE CT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.

The MODEL GF1061PT Voltage Transformer Analyzer is designed for testing current transformers (CT) and potential transformers (PT) without interruption of the customer’s service. This instrument measures CT admittance, CT ratio, CT primary-to-secondary phase angle and the voltage, current and phase angle of the service.

Sophisticated testing of inductive and capacitive voltage transformers GF1061PT is the first portable device which offers highly accurate voltage transformer tests. This allows to use GF1061PT not only for electrical performance checks, but also for class verification and calibration.

FUNCTIONS

Injects low test signals into secondary side of the CT

Determines the CT‘s equivalent circuit parameters

Identifies all relevant CT performance parameters

Displays all relevant parameters of the CT and its accuracy at different currents and burdens

Evaluates the CT according to the selected standard

Determines unknown CT nameplate parameters

Demagnetizes the CT after the test

Ratio and phase accuracy
Winding resistance
Excitation characteristics (knee points)
Composite error (ALF, ALFi, FS, FSi, Vb)
Burden impedance
Transient CT classes and parameters
(TPS, TPX, TPY and TPZ type CTs)
Transient dimensioning factor (Ktd)
If missing/unknown: CT type, class, ratio, knee point, power factor, nominal burden, operating burden, primary and secondary winding resistance
Remanence and residual magnetism
Immediate good/bad evaluation

Features

1. Steady and transient state characteristic tests of various types of CT/PT

2. The use of advanced power technology, the test knee point reaches up to 50kV

3. No external other auxiliary equipment, stand-alone to complete all test items

4. CT test, easy to test, all the tests are using the same wire connection except the load test

5. It carries with thermal printer, so it can print test results on site Reference Standard IEC 60044, ANSI/ IEEE C57.13, IEC61869, GB 1207-2006, GB 1208-2006

6. Parameters such as knee point current and voltage

7. Parameters such as 10% error curve, 5% error curve

8. With battery, working 7days.

9. The device can store 10000 groups of test data which would not be lost if the device is power off.

10. The data can be displayed and analyzed after the test, or transferred to PC through USB disk and produce a Word file report

11. Portability: weight <4kg, the best light ct analyzer

MAIN FUNCTIONS

I. Current Transformer (CT) II. Voltage Transformer (PT)
1. Magnetization curve 1. Excitation characteristic test
2. Transformation ratio test 2. Transformation ratio test
3. Polarity 3. Polarity
4. 5% and 10% error curve 4. Ratio error, phase error
5. Accuracy limiting factor (ALF) 5. Degauss
6. Degauss 6. Calculation of knee point value
7. Ratio error, phase error 7. Actual secondary load test (burden test)
8. Automatic calculation of excitation knee
point value
8. Resistance test
9. Actual secondary load test (burden test)
10. Resistance test 
11. Secondary time constant (Ts)
12. Remanence coefficient (Kr)
13. Transient dimensioning factor (Ktd)
14. Peak instantaneous error (Er)
15. Magnetizing inductance (LU)
16. Instruments security factor(FS)
17. Composite error

PARAMETERS

Electrical parameters
Accuracy 0.05%
Power supply AC 220V±10% or AC 120V±10%, 50/60Hz or Battery
Output voltage 0-100Vrms
Output current 0-5Arms (20A peak-value)
Output power 0-400 VA (1500 VApeak)
Automatic frequency variation range 0.1-60Hz
Equivalent excitation voltage ≤5000V
Accuracy ≤0.5%
Secondary winding DC resistance measurement Range 0.1-1000Ω
Accuracy ≤0.05%
Secondary actual load measurement Range 5VA-1000VA
Accuracy ≤0.5%±0.1VA
CT/PT phase error measurement Accuracy ±1min (typical) / 3 min (guaranteed)
Resolution 0.1min
CT ratio error measurement Range 1-50000
Accuracy ≤0.05%
PT ratio error measurement Range 1-10000
Accuracy ≤0.05%
Standards 
Reference standards GB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2, ANSI/IEEE C57.13
Safety standards GB 4793.1-2007
EMC EMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2 /3 /4 /6
Mechanical parameters 
Overall dimension (L x W x H) (mm) 280 x 250 x 160
Weight (kg) ≤4
Environmental conditions 
Relative humidity Relative humidity 5%-95% not condensing
Operating temperature -10°C to +50°C
Storage temperature -20°C to +70°C
Altitude ≤1000m

Photo

4.8KG Weight CT PT Analyzer Voltage Transformer Analyzer 0.02% / 0.05% Accuracy

Inquiry Cart 0