Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd. an exclusive current transformer, split core current transformer, current clamp & voltage transformer manufacturer.

Manufacturer from China
Active Member
8 Years
Home / Products / Electric Meter Calibration /

0.05% Accuracy 576V 120A Portable Three Phase Electric Meter Calibration

Contact Now
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
City:beijing
Province/State:beijing
Country/Region:china
Contact Person:Andy
Contact Now

0.05% Accuracy 576V 120A Portable Three Phase Electric Meter Calibration

Ask Latest Price
Video Channel
Brand Name :GFUVE
Model Number :GF312D1-100A
Certification :CE, ISO9001, KEMA, UL
Place of Origin :BEIJING CHINA
MOQ :1SET
Price :Negotiable
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :200SET/MONTH
Delivery Time :2-3weeks
Packaging Details :Standard Export wooden Box
Name :Three Phase Electric Meter Calibrator
Accuracy :0.05%
Relative humidity :15%-85%
Resolution :6”TFT (640×480)
Instrument Weight :1.8kg
Harmonics :2nd-64st
Current measurement direct :0-20A
Clamp on ct :0-120A
Voltage :0-576V
Function :electric meter error testing
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

GF312D1 0.05% Accuracy 576V 120A Portable Three Phase Electric Meter Calibrator With 100A clamp on ct

GF312D1 Portable Three Phase Electric Meter Calibrator With 100A clamp on ct is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure all various of AC parameters.

Calibration of electricity meters An electricity meter or a watthour meter measures the electrical energy passing through the meter and may be single-phase or poly-phase.

Application

The devices used to calibrate electricity meters must be routinely verified themselves. That’s the only way to protect consumers. Laborelec’s working standards are well suited to the task. We can carry out calibration on your site, minimising disruption to your calibration routine.

Laborary has a fully equipped calibration equipment with the most accurate energy standard. It can furnish an extensive accreditation portfolio that is recognised internationally.

FEATURES

  1. Three phase active or reactive electricity energy meter.
  2. Calibrate three phase, single phase, and active or reactive meter error.
  3. Measure U(voltage) of three phase or single phase.
  4. Measure I(current) of three phase or single phase.
  5. Measure active power of three phase or single phase.
  6. Measure reactive power of three phase or single phase.
  7. Measure apparent power of three phase or single phase.
  8. Measure power factor of three phase or single phase.
  9. Measure phase angle between voltage and current.
  10. Measure frequency of power line.
  11. Display vector diagram.
  12. Display waveform of U and I.
  13. Analyze and display content of harmonic of U and I.
  14. Measure 2-64 harmonic of U, I.
  15. Store and display measured data.
  16. Optional 5A, 20A, 100A, 500A, 1000A, 2000A, 3000A current clamp.
  17. Measure CT variable ratio.
  18. Measure the ratio or lag-angle of low-voltage transformer.
  19. Adopt 32 bit ARM processor, multi-channel 16 bit precision A/D convertor, high resolution TFT color LCD.
  20. Inner equipped with 0.01% wide-range current transformer and can be equipped with various type current clamps, wide range of measurement and high veracity.
  21. Low consumption circuit design, high energy Lithium battery supply, intellectual power management software, which enables the instrument continuously working up to 10 hours.

PARAMETERS

Electrical parameters  
Accuracy class 0.05%, 0.1%
Resolution 6”TFT (640×480)
Power supply 220V±10%, 50/60Hz
Li-polymer battery (size (mm): 110x51x16, nominal output voltage: 7.2V, capacity: 5000mAh)
Power line supply (U1, UN), 85V-265V 50/60Hz
Communication port RS232
Test voltage  
Range 0-480V
Error ±0.05% (30V-480V)
  ±0.1% (5V-30V)
Harmonic 2nd-64st
Test current  
Range (direct connection) 5mA-20A
Error (direct connection) ±0.05% (100mA-20A)
±0.1% (10mA-100mA)
Range (clamp CT) 10mA-3000A
Error (camp CT) ±0.2% (100mA-100A)
±0.5% (100A-3000A)
Harmonic 2nd-64st
Power measure error  
Active power (direct connection) ±0.05% (0.1A-20A)
±0.1% (0.01A-0.1A)
Reactive power (direct connection) ±0.1% (0.1A-20A)
Energy measure error  
Active energy (direct connection) ±0.05% (0.1A-20A)
±0.1% (0.01A-0.1A)
Reactive energy (direct connection) ±0.1% (0.1A-20A)
Phase angle  
Range 0o-360o
Resolution 0.01o
Error ±0.05o
Frequency  
Range 45-65Hz
Resolution 0.001Hz
Error 0.002Hz
Pulse input  
Input channel 2
Input level 5-24V
Input frequency Max. 2MHz
Pulse output  
Energy constant 180000imp/kWh, 1800imp/kWh, 180imp/kWh
Pulse ratio 1:1
Output level 5V
Function  
Vector diagram Yes
Waveform Yes
Energy accumulation Yes
Communication with PC Yes
Mechanical parameters  
Instrument dimensions (W×H×D) (mm) 245×162×60
Instrument Weight (kg) 1.8
Carry case dimensions (W×H×D) (mm) 450×320×185
Carry case (kg) 10.6
Environmental conditions  
Ambient temperature -10°C to 55°C
Relative humidity 15%-85%

0.05% Accuracy 576V 120A Portable Three Phase Electric Meter Calibration0.05% Accuracy 576V 120A Portable Three Phase Electric Meter Calibration

Inquiry Cart 0