Three Phase Power Quality Analyzer Data Logger , Power Harmonics Analyzer 120-400V

Contact Now
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
City:beijing
Province/State:beijing
Country/Region:china
Contact Person:Andy
Contact Now

Three Phase Power Quality Analyzer Data Logger , Power Harmonics Analyzer 120-400V

Ask Latest Price
Video Channel
Brand Name :GFUVE
Model Number :E6000
Certification :CE
Place of Origin :Beijing, China (Mainland)
MOQ :1 SET
Price :Negotiable
Packaging Details :aluminum alloy box
Measuring range/resolution :5A/50A/100A/500A/1200A/3000A/6000A(Flexible Current Clamp)
Measuring Vol :120-400V
Input channels :4 phase voltage, 4 phase current
Window points :5120 points every 10 cycles
Power supply  :110V-240V
Weight :2KG
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Handheld Three Phase Power Quality And Energy Analyzer

E6000 handheld three phase power quality analyzer with CT offer the best ability in power quality analysis, E6000 handheld power quality analyzer help locate, predict, prevent and troubleshoot power quality problems in three phase and single phase power distribution systems. Additionally, GFUVE patented energy loss algorithm, unified power measurement, measuring and counting energy losses due to harmonics and unbalance issues, allowing the user to pinpoint the origin of energy losses in the system.

FEATURES

  • 3s statistical interval, continuously record 120h;
  • Support multi-brand current transformer;
  • Up to 8G data storage space;
  • Record up to 461 power energy parameters simultaneously;
  • Up to 6500 screenshots saved;
  • Support periodic recording function;
  • Up to 3.9M/s USB high-speed transfer;
  • Customized international report generation.

Electrical parameters 
Voltage rms, ava, pk+, pk-, rms-1/2, CF
Frequency Freq
Current rms, ava, pk+, pk-, rms-1/2, CF
Power & energy P, S, Q, PF, DPF, W
Computation THD, DC, 1-50 Harm, 1-50 InHarm, 1-35 HiHarm, 1-50 SubHarm
Voltage harmonic THD, DC, 1-50 Harm, 0-49 InHarm, 1-35 HiHarm, 1-50 SubHarm , KF
Current harmonic THD, DC, 1-50 Harm
Harmonic power Ia, Ib, Ic, ΣPtotal, ΣQtotal, ΣStotal, 15 minutes
Fluctuation and flickering PST, PLT, Fluct, Fluct Max
Unbal V Pos, A pos , V neg , A neg , V zero, A zero, Unbal
Event log Voltage swell, voltage sags, DIP, surge current, voltage and current distortion out of limit, odd harmonics containing rate out of limited, unbalanced voltage current out of limit, frequency out of limit, PST out of limit, PLT out of limit, long-term voltage interruption, voltage fluctuation deviation
P, Q, S name 
Measurement types P: Calculate by every 10 cycles
S: Calculated by the effective value of voltage and current
Q: Calculated by the apparent power, active power
Display Table charts, trend chart
Measuring range/resolution According to the range of the voltage and current
measuring accuracy ±0.5%
Arms 
Measurement mode Calculated by the square root value of 10 cycle
Display mode Effective current value of each channel
Measuring range/resolution Current: according to the current clamps
Option:5A/50A/100A/500A
Current clamps: 1200A/3000A/6000A(Flexible Current Clamp)
Accuracy 0.1% + accuracy of the current clamps
Frequency 
Measurement mode Calculate by 10 cycles (50Hz) or (60Hz)
Display mode Measurement by 10 cycles
Nominal frequency/resolution 50.000Hz/0.001Hz or 60.000Hz/0.001Hz
Bandwidth measurement 42.5-57.5Hz or 52.5-67.5Hz
Measurement accuracy ±0.001Hz
Half-wave RMS current/voltage 
Measurement mode Calculate by every 2 cycles. Each cycle ,1/2 cycle made up of a waveform calculation
Measuring range/resolution Voltage: 120V/0.01V, 230V/0.01V, 400V/0.01V, 1000V/0.01V,Current: According to the current clamps
measurement accuracy ±0.1%
Vrms 
Measuring circuit 1P2W/ 2P3W /3P3W/ 3P4W
Basic frequency of the measuring circuit 50Hz
Input channels 4 phase voltage, 4 phase current
Measurement range Voltage measurement range: standard: 120V, 230V, 400V, 1000V, Max 1000V instantaneous voltage
Current measurement range: according to the current clamps, only support the v signal output current clamp
Power factor 
Measurement mode The ratio of average power to apparent power
Display mode Real-time data showed
Measurement range/resolution -1.000-1.000/0.001
Measurement accuracy ±1%
Vfund, Afund, Harmonic power 
Measurement mode Meet IEC61000-4-7,Analysis time window is ten cycles
Window points 5120 points
Display mode Form figure, trend charts, histograms
Number of measurement 1-50 Times
Measurement accuracy Vfund >1%: Error<1%
Vfund <1%: Error<0.05% Rated Voltage
Afund >3%: Error<1%
Afund <3%: Error<0.05% Current range
InHarm Voltage, InHarm current 
Measurement mode Meet IEC61000-4-7, Analysis time window is ten cycles
Window points 5120 points
Display mode Form figure, trend charts, histograms
Numbers of measurement 1-16 groups
Measurement accuracy Vfund >1%: Error<1%
Vfund <1%: Error<0.05% Rated Voltage
Afund >3%: Error<1%
Afund <3%: Error<0.05% Current range
HiHarm Voltage, HiHarm current 
Measurement mode Meet IEC61000-4-7, Analysis time window is ten cycles
Window points 5120 points every 10 cycles
Display mode Form figure, trend charts, histograms
Numbers of measurement 1-35 groups
Measurement accuracy Vfund >1%: Error<1%
Vfund <1%: Error<0.05% rated voltage
Afund >3%: Error<1%
Afund <3%: Error<0.05% current range
Voltage SubHarm Current SubHarm 
Measurement mode Meet IEC61000-4-7, analysis time window is ten cycles
Window points 5120 points every 10 cycles
Display mode Form figure, trend charts, histograms
Numbers of measurement 1-50 groups
Measurement accuracy Vfund >1%: Error<1%
Vfund <1%: Error<0.05% Rated Voltage
Afund >3%: Error<1%
Afund <3%: Error<0.05% Current range
Voltage/current Unbal (pos, neg) 
Measurement mode 3P3W or 3P4W, using three phase of fundamental wave components to calculate
Display mode Form figure, trend charts, histograms
Measurement accuracy Voltage unbal: ±0.2%
Current unbal: ±0.5%
Voltage fluctuation 
Measurement mode Calculate by the quadratic mean of half wave.
Display mode Form figure, trend charts
Measurement accuracy ±1%
IEC Flickering 
Measurement P short term (Pst) , P long term (Plt)
Measurement mode According to IEC61000-4-15 Standard to calculate Pst (10 mins) Plt (2 hours)
Display mode Form figure, trend charts
Measurement range 0-20
Measurement accuracy ±5%
Surge current 
Measurement mode Half-wave RMS of current is higher than set value and sustain time is 10ms-1min
Display mode Maximum of the surge current and surge current wave
Measurement accuracy 0.10%
Voltage swell, Voltage sags, DIP 
Measurement mode Swell: When half-wave RMS of voltage is higher than set value and sustain time is 10ms-1min, judged as swell.
Sags: When half-wave RMS of voltage is lower than set value and sustain time is 10ms-1min, judged as sags.
DIP: half-wave RMS of voltage is higher than set value and sustain time is 10ms-1min, judged as DIP
Display mode Swell, sags, DIP wave sustain time, extent and so on.
Measurement accuracy 0.10%
Machinery 
Size 263mm x 168mm x 65mm
Weight 2KG
Power supply 
Voltage input 110V-240V
Adapter output 15V, 3A
Battery Rechargeable nickel metal hydride, 4500mAh
Battery working time 4h
Battery recharging time 5h (Environment temperature 25°C)
Power saving facility LCD backlight brightness is adjustable, standby time is adjustable
Display 
Size 112.8 x 84.6mm
Color 260000 color
Resolutions 640 x 480
Brightness Max 350 cd/m2 (Typ), brightness is adjustable
Contrast 500:1 (Typ)
Visual angle 70/70/50/70 (Typ.)(CR ≥10) ( Left/ Right/ UP/Down)
Store 
Type TF card (inbuilt)
Size 8G
Standards 
Measurement method IEC 61000-4-30
Measurement performance IEC 61000-4-30 A LVL
Flickering IEC 61000-4-15
Harmonic IEC 61000-4-7
Safety 
Standard GB 4793.1-2007/IEC 61010-1:2001: "Measurement, control and laboratory electrical equipment safety requirements", first part: general requirements.
Security level: CAT III 1000 V/ CAT IV 600 V.
MAX voltage of phase angle input CAT III 1000V/CAT IV 600V
Environmental conditions 
Working environment 0°C to +45°C, humidity below 90rh%
Storing environment -20°C to +50°C, humidity below 95rh% (non-condensing)

Three Phase Power Quality Analyzer Data Logger , Power Harmonics Analyzer 120-400V