
Add to Cart
Application
It is suitable for power department, measuring department, quality control department, research units, and institutions of higher learning, and electric energy meter, power distribution terminals, power supply management, load control, power quality, reactive power compensation device and the production of enterprise etc.
Functions and Features
Accuracy class | 0.05%, 0.1% |
Power supply | Single phase AC 85-265 V, frequency 50/60 Hz |
AC Voltage output | |
Range (U1, U2, U3 phase) | 57.7V / 100V / 220V / 380V; range switch automatically(Max 500V) |
Adjust fineness | 0.01% RG |
Accuracy | 0.05% RG |
Stability | |
Distortion degree | <0.3% (not capacitive load) |
Output power | 25VA |
Full load regulation rate | 0.01% RG |
Full load regulation time | Less than 1mS |
Long-term stability | ± 60 PPM/year |
AC Current output | |
Range (I1, I2, I3 phase) | 0.2A, 1A, 5A, 20A, 100A; range switch automatically |
Adjustment range | (0-120)%RG |
Adjust fineness | 0.01% RG |
Accuracy | 0.05% RG |
Stability | <0.01% RG / 120 s |
Distortion degree | <0.3% (not capacitive load) |
Output power | 45VA |
Full load regulation rate | 0.01% RG |
Full load regulation time | Less than 1mS |
Long-term stability | ± 60 PPM/year |
Power output | |
Accuracy | 0.05% RG |
Stability | 0.01% RG/120s |
Phase angle | |
Adjusting range | 0°-359.99° |
Resolution | 0.001° |
Accuracy | 0.05° |
Power factor | |
Adjusting range | -1 ~ 0 ~ +1 |
Resolution | 0.0001 |
Accuracy | 0.0005 |
Frequency | |
Adjusting range | 40-65 Hz |
Resolution | 0.001 Hz |
Accuracy | 0.005 Hz |
Temperature drift | ± 0.5 PPM /°C |
Long-term stability | ± 4 PPM/year |
Harmonic accuracy | |
Harmonic phase | 0°-359.99° |
Harmonic phase accuracy | < 0.01° |
Harmonic set accuracy | 0.1% (relative to the base wave ratings) |
Mechanical parameters | |
Dimensions (W×D×H) (mm) | 500x600x175 |
Weight (kg) | 27 |
Environmental conditions | |
Working temperature | 0°C to 40°C |
Storage condition | -30°C to -60°C |
Relative humidity | ≤ 85% |