Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd. an exclusive current transformer, split core current transformer, current clamp & voltage transformer manufacturer.

Manufacturer from China
Active Member
8 Years
Home / Products / Instrument Current Transformer /

ANSI 5A Combined Outdoor Instrument Transformer Epoxy Resin Insulated Casting

Contact Now
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
City:beijing
Province/State:beijing
Country/Region:china
Contact Person:Andy
Contact Now

ANSI 5A Combined Outdoor Instrument Transformer Epoxy Resin Insulated Casting

Ask Latest Price
Video Channel
Brand Name :GFUVE
Model Number :GFLZZ0954-10E
Certification :CE , ISO9001
Place of Origin :BEIJING CHINA
MOQ :3 PCS
Price :Negotiable
Payment Terms :T/T, Western Union, MoneyGram
Supply Ability :10000 PCs / Month
Packaging Details :Standard Export Carton Box
Name :MV Current Transformer Instrument
Rated primary current :5-1250A
Class :0.2s , 0.5
Standards :50Hz or 60Hz
Rated secondary current :5A or 1A
Rated insulation level :12/42/75KV
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Presicion ANSI 5A CTs Current Transformer Instrument

The dry type current transformers GFLZZ0954-10E are cast in epoxy resin insulated with big surface creepage distance and are excellent in anti-pollution and humidity protection . With high grade accuracy, it is suitable for protection against large short-circuit current , secondary current output 1A or 5A . The performances of the products meet standards IEC60044-1, IEC61869-2 and ANSI/IEEE C57.13 .

Technical parameters 
Standards IEC60044 ; IEC 61869 ; ANSI/IEEE C57.13
Rated primary current 5-1250A
Rated load ≤15VA
Rated frequency 50Hz or 60Hz
Rated secondary current 5A or 1A
Rated short-time thermal current 140kA , 1S
Rated dynamic current 350KA
Rated insulation level 12 / 42 / 75KV
FS ≤ 10
Mechanical parameters 
Material Epoxy resin
Weight (kg) 32
Operating conditions 
Operating temperature -25°C to +55°C
Daily average temp < + 40°C
Storage temperature - 40°C to +70°C
Altitude <1000 meters
Condition No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.

TECHNICAL PARAMETERS

Ratied Primary Current(A) Class Combination Accuracy class and Rated output(VA) Short-time thermal current(kA/S) Rated dynamic current(kA)
0.5 10P10
5-150

0.2(S)/10P10

0.5/10P10

10 15 150 I1n 375 I1n
200 36 90
300 45 100
400-600 63 150
800-1000 100 250
1250 140 350

ANSI 5A Combined Outdoor Instrument Transformer Epoxy Resin Insulated Casting