Indoor 10KV Low Voltage High Current Transformer Accuracy Class 0.5 Multiple Installation

Ask Latest Price
Video Channel
Brand Name :GFUVE
Model Number :GFLZZ0973-10G2
Certification :CE, UL, KEMA, ISO9001
Place of Origin :BEIJING CHINA
MOQ :3 PCS
Price :Negotiable
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :10000 PCS/MONTH
Delivery Time :2-3 weeks
Packaging Details :Standard Export Carton Box
Name :Resin 10KV Accuracy Class 0.5 Instrument Current Transformer Indoor
Rated primary current :5-1250A
Rated load :≤15VA
Rated secondary current :5A or 1A
Material :Epoxy resin
Weight :25kg
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Resin 10KV Accuracy Class 0.5 Instrument Current Transformer Indoor

Introduction

Instrument transformers are high accuracy class electrical devices used to isolate or transform voltage or current levels. The most common usage of instrument transformers is to operate instruments or metering from high voltage or high current circuits, safely isolating secondary control circuitry from the high voltages or currents. The primary winding of the transformer is connected to the high voltage or high current circuit, and the meter or relay is connected to the secondary circuit.
Instrument transformers may also be used as an isolation transformer so that secondary quantities may be used in phase shifting without affecting other primary connected devices.
Current transformers (CT) are a series connected type of instrument transformer. They are designed to present negligible load to the supply being measured and have an accurate current ratio and phase relationship to enable accurate secondary connected metering.
Current transformers are often constructed by passing a single primary turn (either an insulated cable or an uninsulated bus bar) through a well-insulated toroidal core wrapped with many turns of wire. This affords easy implementation on high voltage bushings of grid transformers and other devices by installing the secondary turn core inside high-voltage bushing insulators and using the pass-through conductor as a single turn primary.


PARAMETERS

Technical parameters  
Standards IEC60044; IEC 61869; ANSI/IEEE C57.13
Rated primary current 5-1250A
Rated load ≤15VA
Rated frequency 50Hz or 60Hz
Rated secondary current 5A or 1A
Rated short-time thermal current 140kA, 1S
Rated dynamic current 350kA
Rated insulation level 12/42/75KV
FS ≤10
Mechanical parameters  
Material Epoxy resin
Weight (kg) 25
Operating conditions  
Operating temperature -25°C to +55°C
Daily average temp <+40°C
Storage temperature -40°C to +70°C
Altitude <1000 meters
Condition No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.


TECHNICAL DATA

Ratied Primary Current(A) Class Combination Accuracy class and Rated output(VA) Short-time thermal current
(kA/S)
Rated dynamic current
(kA)
0.5 10P
5-150 0.2(S)/10P
0.5/10P
10 15 150 I1n 375 I1n
200 36 90
300 45 100
400-600 63 150
800-1000 100 250
1250 140 350


Overall Dimensions

Indoor 10KV Low Voltage High Current Transformer Accuracy Class 0.5 Multiple Installation