Add to Cart
Program-controlled Single Phase Phantom Load Power Source
1 . Setting up and taking the load regulation of voltage, current, phase and frequency of the power factor
2 . Amplitude 2nd-128th phase harmonics, and it can be added to the fundamental wave in every harmonic output
3 . A wide range output of voltage and current, big power, high stability, small waveform distortion degree
4 . Strong load ability, taking capacitive load, sensibility load, resistive load or composite load, load regulation is higher than 0.01%
5 . Applying the 32-bit MPU + DSP + FPGA, powerful flexible;
6 . Using hardware PID, fast response, the change of load will not cause volatility output.
7 . Power frequency waves reach up to 50000 points a week of the wave kneading, signal output without filter, precise waveform output, precise harmonic output, small harmonic distortion degree
Parameters
Electrical parameters | |
Accuracy class | 0.05%, 0.1% |
Power supply | Single phase AC 85-265V, 50/60 Hz |
AC Voltage output | |
Range | 57.7V / 100 V / 220V / 380V, Switch automatically (max 500V) |
Adjustment resolution | 0.01%, 0.1%, 1%, 10%, |
Accuracy | 0.05% RG |
Stability | Better than 0.01% RG / 1 min |
Distortion degree | Better than 0.1% (not capacitive load) |
Load capacity | 40VA |
Full load regulation rate | Less than 0.01% RG |
Full load regulation time | Less than 1ms |
Temperature drift | 8 PPM / °C |
Long-term stability | 60 PPM/year |
AC Current output | |
Range | 0.1A / 0.25A / 0.5A / 1A / 5A / 10A / 20A / 50A / 100A, Switch automatically |
Adjustment resolution | 0.01%, 0.1%, 1%, 10%, |
Accuracy | 0.05% RG |
Stability | Better than 0.01% RG/1 min |
Distortion degree | Better than 0.1% (not capacitive load) |
Load capacity | 40VA |
Full load regulation rate | Less than 0.01% RG |
Full load regulation time | Less than 1mS |
Temperature drift | 8 PPM / °C |
Long-term stability | 60 PPM/year |
Power output | |
Active power accuracy | 0.05% or 0.1% |
Reactive power accuracy | 0.1% or 0.2% |
Stability | Better than 0.01% RG / 1 min |
Phase | |
Range | 0°-359.99° |
Adjustment resolution | 0.01°, 0.1°, 1°, 10° |
Accuracy | 0.03° |
Frequency | |
Range | 40-65 Hz |
Adjustment resolution | 0.001 Hz, 0.01 Hz, 0.1 Hz, 1Hz |
Accuracy | 0.002 Hz |
Temperature drift | 0.5 PPM / °C |
Long-term stability | 4 PPM/year |
Harmonic | |
Harmonic times | 2nd-63th |
Adjustment resolution | 0.1% (Compared with fundamental wave) |
Harmonic content (Compared with fundamental wave) | |
Voltage | ≤ 40% |
Current | ≤ 40% |
Phase | 0°-360° |
Mechanical parameters | |
Dimensions (W×D×H) (mm) | 420x320x155 |
Weight (kg) | 12 |
Environmental conditions | |
Operating temperature | 0°C to 40°C |
Storage conditions | -30°C to 60°C |
Relative humidity | ≤85% |