Current Transformer Permalloy Split Core Current Probe for 50mm Cable
The round jaw design on the P50-1 Series Permalloy Split Core Current Probe along with the high content nickel metal core makes them well suited for power quality applications where high accuracy and low phase shift along with wide frequency are important. Measurement range is 1mA to 1200A.
The AC Current Probe P50-1 is a general purpose 1000A AC current probe designed for use with DMMs, loggers and other instruments that have a current input. It has a 1000:1 ratio and output of 1mA per amp or 1mV per amp measured in the jaw. The P50-1 has an integral 2.5m lead terminated. The rounded jaw design on this probe makes it well-suited for power applications where high accuracy 0.1% and low phase shift and wide frequency response are important.
Current probes are key to the successful design of electrical devices, and electronic parts. The GFUVE current probes P50-1 is a high-safety current clamp providing accurate current measurements without breaking down electricity. so costly down time can be eliminated.
GFUVE probes should be used below 600 volts, P50-1 can customize output with A, mA, V, mV.
If you cannot find information you need or would like assistance, please contact us today. We have designed many more probes than those shown in this catalog, and we manufacture in Beijing, China.
Features
Measurement range of 1mA to 1200A AC
Large jaw opening accommodates conductors up to two 500kcmil
Improved ergonomic design and easy operation
High content nickel metal core
Conforms to EN 61010, 600V CAT III
Low phase shift for power measurement
Designed for DMMs, recorders, loggers, oscilloscopes, power and harmonic meters
UL, CE mark
Applications
Power quality measuring
Large industrial loads
Measuring around cable bundles
Power load monitoring
Waveform analysis
Energy meter calibrator
Parameter
Electrical parameters | |
Ratio | 1000: 1 or 2000:1 (customized) |
Accuracy class | 0.1%, 0.2%, 0.5% |
Primary current | 0 - 1000A AC |
Secondary output | 1mV/A AC, 5mV/A or (customized) |
Max. Cont. Input current | 1200A |
Over voltage category | CAT III 600V |
Output signal | 333mV, 500mV,1V,2V,5V AC at nominal input current |
Accuracy (1000A Range) | |
0-10A | ≤0.5% |
10-100 | ≤0.2% |
10-1200A | ≤0.1% |
Phase Shift(1000A Range) | |
0-10A | ≤0.5° |
10-100 | ≤0.2° |
100-1200A | ≤0.1° |
Frequency range | 40Hz-2000Hz |
Dielectric strength | 3KV 50Hz/60Hz at 1 minute |
Temperature range | -20°C to +55°C |
Output | 2.5 meter cable with D01 connector |
Max. voltage not insulated conductors | 600 V |
Standard | EN 61010-1, EN 61010-2-032, IEC60044-1 |
Installation | Clamp type |
Output mode | Lead output (2.5m) |